aiotestking uk

HPE0-S60 Exam Questions - Online Test


HPE0-S60 Premium VCE File

Learn More 100% Pass Guarantee - Dumps Verified - Instant Download
150 Lectures, 20 Hours

It is more faster and easier to pass the HP HPE0-S60 exam by using Tested HP Delta - HPE Compute Solutions questuins and answers. Immediate access to the Up to date HPE0-S60 Exam and find the same core area HPE0-S60 questions with professionally verified answers, then PASS your exam with a high score now.

Also have HPE0-S60 free dumps questions for you:

NEW QUESTION 1
Match HPE SimpliVity term with the definition.
HPE0-S60 dumps exhibit


Solution:
HPE0-S60 dumps exhibit

Does this meet the goal?
  • A. Yes
  • B. Not Mastered

Answer: A

NEW QUESTION 2
What is a limitation when creating a server profile?

  • A. BIOS settings can be changed only when UEFI optimized is selected as boot mode
  • B. ILO management is limited to the integration with Active Directory or LDAP
  • C. Administrator cannot define more than 8 connections within a server profile
  • D. It is not possible to create shared volumes on demand through a server profile

Answer: B

NEW QUESTION 3
Put the steps of the HPE infosight flow in the correct order.
HPE0-S60 dumps exhibit


Solution:
(observing, learning, predicting, recommending, acting)

Does this meet the goal?
  • A. Yes
  • B. Not Mastered

Answer: A

NEW QUESTION 4
Which statement about an HPE Oneview support dump is true?

  • A. Appliance support dump by default contains a logical enclosure support dump
  • B. Support dump is a binary file that can be opened only in a dedicated application
  • C. Support dump can be created if HPE Virtual Connect modules are installed in the frame
  • D. Preview support dump is available only when creating an appliance support dump

Answer: B

NEW QUESTION 5
Your customer experienced some problems caused by outdated HPE Superdome Flex firmware. Which update method should they use to avoid these issues in the future?

  • A. HPE OneView method for I/O firmware update procedure
  • B. RMC CLI to update I/O and HPE Persistent Memory firmware
  • C. HPE OneView IT HPE Persistent Memory firmware must be updated.
  • D. HPE SUM if HPE Persistent Memory firmware must be updated

Answer: B

NEW QUESTION 6
As a result of the troubleshooting process, you recommend replacing, HPE Synergy Composer modules which HPE Synergy Composer 2
Why would you recommend this change?

  • A. HPE Composer 1 running HPE OneView 5 2 or later can support only 12 frames within a single management nog
  • B. HPE Composer 2 can support more than the maximum 21 frames that are supported with HPE Composer 1 and HPE OneView.
  • C. HPE Composer 2 provides access to 105 interface that can be used for full management of HPE Composer 2 remotely
  • D. HPE Composer 1 cannot support remote frames, which doubles the configuration and management procedures effort

Answer: B

NEW QUESTION 7
Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They plan to use Distributed Switches and DRS cluster
You are preparing a proposal with the following components:
- HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules
- two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- an appropriate number of the vSphere Standard licenses for each compute node
- one HPE D3940 Storage Modules with 40 SSDs - all required cables and options Which statement about this proposal is true?

  • A. One HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50GD/S ILM
  • B. vSphere Standard licenses should be replaced with Enterprise Pius licenses to enable requested features
  • C. 2 additional HPE Synergy 480 Gen10 Plus compute modules can be added to this setup
  • D. 20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drive.

Answer: B

NEW QUESTION 8
Which statement about HPE Superdome nPars is true?

  • A. Chassis in the same nPar can have different CPU configuration
  • B. Rack Management Controller is required Tor nPar configuration
  • C. Chassis in the same nPar can have different memory configuration
  • D. nPars are supported only with 3rd Generation Intel Xeon Scalable Processors

Answer: C

NEW QUESTION 9
Which statement about HPE Superdome Flex 280 is true?

  • A. It supports 2 to 8 sockets in 2-socket increments.
  • B. it cannot be managed using HPE OneView.
  • C. It must be equipped with at least 768 GB of memory.
  • D. It can support up to two nPars with an external RMC.

Answer: C

NEW QUESTION 10
Your customer wants to compare HPE Superdome Flex with HPE Superdome Flex 280. Which statement about these two systems is true?

  • A. Only HPE Superdome Rex 280 can be managed using HPE OneView
  • B. Only HPE Superdome Flex supports HPE Persistent Memory
  • C. Only HPE Superdome Flex 280 can support multiple nPars
  • D. Only HPE Superdome Flex supports 32 sockets and 48TB of memory

Answer: A

NEW QUESTION 11
Your customer plans to setup an HPE Synergy solution based on SY480 Gen10 compute nodes with the following connectivity options - SAS connectivity installed in the first fabric - FC connectivity Installed In the second fabric - Ethernet connectivity installed in the third fabric.
Which statement regarding this setup is true?

  • A. Each compute node must have at least 768GB of memory installed
  • B. Interconnect modules that provide SAS connectivity should be moved to the third fabric
  • C. Each interconnect module in each fabric must be properly licensed in HPE OneView
  • D. Compute nodes must have a second CPU installed to access the second fabric.

Answer: A

NEW QUESTION 12
Your customer reports that they cannot deploy HPE Synergy compute nodes using HPE OneView for VMware vCenter Server (HPE OV4VC).
What should you check during troubleshooting process?

  • A. If HPE OneView credentials are added in vCenter Server
  • B. If an compute nodes are added to the vCenter Server
  • C. If the HPE Oneview instance Is integrated with HPE OV4VC.
  • D. If vCenter Server is licensed in the HPE Oneview interface

Answer: B

NEW QUESTION 13
Your customer plans to deploy HPE OneView for VMware vCenter Server together with HPE Storage Integration Pack for VMware vCenter. The customer wants to use them to manage HPE Synergy Gen10 compute modules. HPE ProLiant Gen 10 servers and an MSA array.
Which statement about compatibility of the existing environment with the planned software components is true?

  • A. Both HPE Synergy Gen10 full-height compute module plugins will require a license
  • B. HPE OneView for VMware vCenter Server does not support standalone HPE ProLiant servers
  • C. To use the required plugins HPE ProLiant Gen10 systems must be managed using HPE OneView
  • D. HPE Storage integration Pack for VMware vCenter does not support MSA arrays

Answer: B

NEW QUESTION 14
Your customer has an HPE Synergy platform deployed and managed using HPE OneView. The customer also has HPE Superdome Flex with RMC deployed They plan to deploy a second nPar and HPE Superdome Flex 280 They plan to manage new components using HPE OneView
What must be done to achieve this goal?

  • A. The customer must use IL05 to add HPE Superdome Flex systems to HPE OneView
  • B. The customer should deploy an HPE OneView appliance for HPE Superdome Flex management
  • C. The customer must add a second Rack Management Controller for HPE Superdome Flex 280
  • D. The customer has to add HPE Superdome Flex to the HPE OneView used to manage HPE Synergy

Answer: C

NEW QUESTION 15
Your customer plans to deploy VMware ESXi 7 0 U2 and they are looking for a hardware platform mat wilt allow them to use up to 24 TB of physical memory.
Which HPE compute system meets this customer's requirements?

  • A. HPE ProLiant DL380 Gen 10 Plus
  • B. HPE Synergy 480 Gen10 Plus
  • C. HPE ProLiant DL560 Gen10
  • D. HPE Superdome Flex 280

Answer: A

NEW QUESTION 16
In the past a customer experienced a networking issue where network ports went down and came back up in quick succession.
Which HPE Virtual Connect SE 100 GD F32 Module for HPE Synergy feature can be configured to disable such ports?

  • A. Pause flood protection
  • B. sFlow
  • C. Storm control
  • D. Port flap protection

Answer: B

NEW QUESTION 17
A logical interconnect group can span on multiple HPE Synergy frames for which interconnect type?

  • A. Brocade 32GB Fibre Channel Switch Module for HPE Synergy
  • B. HPE virtual Connect SE 32 Gb FC Module for Synergy
  • C. HPE Virtual Connect SE 100 Gb F32 Module tor Synergy
  • D. HPE Synergy 12 Gb SAS Connection Module

Answer: C

NEW QUESTION 18
Your customer wants to add a second HPE Synergy frame to an existing logical enclosure Based on a single HPE Synergy frame. The customer wants to use a highly available master setup.
Which procedures should De performed during the expansion process? (Select two.)

  • A. Create a new logical interconnect group and enclosure group for two frames setup
  • B. Create a new logical enclosure based on both HPE Synergy frames.
  • C. Re-parent an existing enclosure group to the new logical interconnect group.
  • D. Modify an existing logical interconnect to include second HPE Synergy frame.
  • E. Move one of the master modules to the appropriate interconnect bay in the second frame.

Answer: BD

NEW QUESTION 19
......

Recommend!! Get the Full HPE0-S60 dumps in VCE and PDF From Dumpscollection.com, Welcome to Download: https://www.dumpscollection.net/dumps/HPE0-S60/ (New 79 Q&As Version)